Re: (ASCEND) MAX1800 stuck BRIs
This is exactly what we see too, every some weeks. M1800 with 5.0Ai13 and
Pipeline-50s dialing in with 64K (no modems in that MAX).
I thought it had something to do with CLID-callback and blamed the telco, hmm.
Alex wrote:
>lqqqqqqqq MAX1800EDIT qqqqqqqqqk lqqqqqqqqqqqqqqqqqqqqklqqqqqqqqqqqqqqqqqqqqk
> x50-000 Ethernet x x10-100 12345678 x x50-300 WAN Statx
> x>50-100 Connections x x Link PP------ x x>Rx Pkt:20701122^x
> x 50-200 Names / Passwords x x B1 r*...... x x Tx Pkt:3309624 x
> x 50-300 Bridge Adrs x x B2 **...... x x CRC:121vx
> x 50-400 Static Rtes x lqqqqqqqqqqqqqqqqqqqqklqqqqqqqqqqqqqqqqqqqqk
>We have this problem on our Max 1800s as well (analog only). When the
>BRI is stuck in the "r" state, there is an Answer in the "show users"
>for that channel. I've seen instances where there is an actually session
>up and running on that, but sometimes people get ring-no-answer as well.
>This was with 5.0Ap16
>
>
Jonathan Lusky wrote:
>> My 1800 POP is all analog callers... so I doubt it's Netopia routers.
>> However, that reminds me of another datapoint. I think every time I've
>> seen this happen, the other B-channel of the BRI did have a connection up.
>>
>>Jason Nealis wrote:
>>>
>>> I have seen this exact problem on my 1800's, Most of the time it seems
>>> to be Netopia Routers on the other side, I was wondering if you have seen
>>> the BRI get stuck in 'r' but actually the session is up and routing.
>>>
Ralf Niederhuefner - hostmaster@prolink.de