Re: (ASCEND) Dial Back Capability Question



>From: "Christopher E. Nichols (Sys Admin)" <chris@worldramp.net>
>  We are going to be setting up a client with a Pipe50 dialing into a Max
>4004.  The catch is that, we need the client to initiate the call, then
>have the Max disconnect the user, then call that user back.  Has anyone
>done this???  I would really appreciate instructions/settings for this setup.

We do this for lots of people in the reverse: we call their Pipelines from
Maxen, they hang up and call back.

A few details need to be set:

The profiles on both sides need to be Ans/Orig=Both.
The box to get called back has Expect Callback=Yes.
The box to do the callback has Callback=Yes.

If you want to place the initial call free, set:
The box to do the callback has CLID Auth=Prefer (at least).

We do this all with local profiles in the Maxen for simplicity. RADIUS is a
whole other story.

Peter Lalor
Infoasis
plalor@infoasis.com
http://www.infoasis.com/
415-459-7991 x102