Re: (ASCEND) Single Vs. Dual Terminal Mode
At 04:01 PM 6/30/98 -0500, Bill Vendramin wrote:
>>At 03:24 PM 6/30/98 -0500, Bill Vendramin wrote:
>>>I have a Pipeline 75 that is having a problem coming online. When it comes
>>>up from a cold state it ends up in single terminal mode
>>>(Line Status showing an M) a lot. When this happens the Pipeline will not
>>>establish a connection. If it initializes into dual terminal mode, there
>are
>>>no problems and it works like a champ - compression and all.
>>>
>>>Anyone have any suggestions as to a) the source of the problem or
>>>b) a way to minimize it?
>>
>>Is the P75 configured with a switch type, or auto-SPID?
>>
>>
>>Kevin Smith Ascend Communications...
>>Customer Satisfaction ...where Network Solutions never end.
>
>Switch Type is NI-1 on a DMS-100 switch through GTE. Both channels
>switched with no leased line connections on the unit.
OK, cool. In that case, if the dual-terminal mode ever works, we
*know* that the configuration in correct. My guess then is that
you either have a bad NT1, or a bad U-interface on the P75 - ;(
Kevin Smith Ascend Communications...
Customer Satisfaction ...where Network Solutions never end.