Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) Callback time to long...



At 04:25 PM 2/20/98 -0800, Kevin A. Smith wrote:
>At 06:17 PM 2/20/98 +0100, Winfried Haug wrote:
>>Hello..
>>
>>we have a customer with a pipeline50 (rel. 5.1A+) which connects to
>>us via Callback. We call him, he calls back. The time until the lan session
>>comes up is 5-6 seconds (8 Pings get lost). This is too long. Competing
>>solutions only have 2-3 seconds... 
>
>Competing solutions??
>
>>The callback call comes in after 2-3 seconds, but it takes 4 seconds
>>until the Lan Session comes up...
>
>RADIUS authentication involved after the call-back?

There are also ISDN connect time improvements in 6.0 that may help. But
Radius delays still apply. On 6.0 I would expect the connect time to be
only 1 second.