Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) PRIs and BUD



Well, I've got NFAS PRI (3 per MAXEN) with first PRI set 23+D, Second
PRI as 23+BUD, and then the third as 24B.  It's worked pretty flawlessly
once we got rid of some minor telco issues.

Granted, that only affords us one channel more than 3 23+D in that config,
but we may add one more PRI per NFAS group in the future.

Regards,
Joe Shaw - jshaw@insync.net
NetAdmin - Insync Internet Services

On Wed, 25 Feb 1998, Paul Emmons wrote:

> Guess what the answer was when I call Ascend:
> Sales - Huh?
> TAC - 	Yes, but had 'never' seen it .and. why would anyone order anything
> but 23B+D?
> 
> Anyone else know?
> 
> Paul
> 
> On Wed, 25 Feb 1998, Joe  Shaw wrote:
> 
> > I'm not sure if NFAS will allow you to put the Backup D channel PRI in
> > another box.  If it doesn't, you could always go with a MAX4000 and plug
> > all the PRI into it.
> > 
> Too many analog modems - Darn
> 
> > Regards,
> > Joe Shaw - jshaw@insync.net
> > NetAdmin - Insync Internet Services
> > 
> > On Wed, 25 Feb 1998, Paul Emmons wrote:
> > 
> > > Is anyone running PRI's in the following configuration on
> > > MAX 4048 and have it work? We have a customer that wants to:
> > > 
> > > Max1    23B+D, 24D
> > > Max2    23BUD, 24D
> > > 
> > > With stacking and OSPF?
> > > 
> > > Thanks in Advance
> > > 
> > > Paul
> > 
> 

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>


References: