Re: (ASCEND) Splitting B channels on a PL75



It has always worked fine for me, and I started back at software 4.6C. Just 
define the two profiles and make sure you don't set them to always use two 
channels. (Base Ch count = Min Ch count = 1).

At 12:55 PM 11/19/1999 -0600, Nate Carlson wrote:
>Just want to make sure that it IS actually possible to split the B
>channels on a Pipe75, and wondering what code revision this started in
>(I've always been told it's not possible in the past, and never saw
>release notes that said it was.) My reason for thinking that it is indeed
>possible comes from Ascend's Product FAQ for the Pipelines. If this is
>indeed possible, is there anything special I need to do to get it working?
>Thanks.
>
>http://www.lucent.com/ins/products/pipeline/pipeline_c.html#7
>
>7.Can these Pipelines place concurrent data calls to different
>destinations?
>
>The Pipeline 50, 75, and 130 support up to eight different Call Profiles.
>The two B-channels of an ISDN BRI line limit the number of concurrent
>different locations to two. Yes, you can "split the B-channels" and
>simultaneously access two different locations with the Pipeline 50 and 75.
>The Pipeline 130's prime function is as a Frame Relay router and allows
>you to specify up to eight diffferent DLCI's with an ISDN BRI
>backup/overflow.
>
>--
>Nate Carlson <carlson@real-time.com>    | Phone : (612)943-8700
>http://www.real-time.com                | Fax   : (612)943-8500
>
>++ Ascend Users Mailing List ++
>To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
>To get FAQ'd:   <http://www.nealis.net/ascend/faq>

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com