Re: (ASCEND) flash error while upgrading p130(4.6A -> 4.6C)



At 02:35 PM 2/1/98 -0800, Terrelle Shaw wrote:
>Ok.. this sucks.. I have a pipeline130 (serial # S/N: 6120353) connected to
>my FR-T1. Im at Software version 4.6A and want to upgrade to the latest by
>way of 4.6C+. when starting the tload from my
>tftp server i get this error:
>flash programing error
>download error - code too large
>----- data lost -----
>download error - code too large

My guess would be that you downloaded the wrong image. p50bria.bin was for the
old architecture P50 - downloads direct to nvram and runs from there. The
image is about 880K in size. The p50brib.bin image loads into flash - and is
then *decompressed* into NVRAM to run - it is only about 420K in size.

>Ok.. maybe thats too big of a jump.. so i go and grab the 4.6bi9 binary..
>Same error.. How can i get this software upgraded without
>the flash being overun with errors. ( i am ftpping the binaries in binary

You didn't say which image you were trying, so I'm guessing it was the
non-compressed version...



Kevin