Ascend Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: (ASCEND) P75 WAN LED issue
At 08:09 PM 2/10/98 -0600, Erick M. Bergquist wrote:
>Hello,
>
> I have a Pipeline 75 (older model with power switch) where the WAN LED
>always stays on yet the unit functions fine. Have upgraded to current
>version of code and still have problem. The WAN LED stays on even when
>there are no cables plugged in the ISDN ports. It works fine but is in a
>end-user environment and they get charged when they are online so with the
>WAN light always on they don't know if its connected or not unless they
>telnet in and check the display. Any ideas or this unit bad?
I would suggest RMAing the unit in that case.
Kevin
++ Ascend Users Mailing List ++
To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd: <http://www.nealis.net/ascend/faq>
Follow-Ups:
References: