Re: (ASCEND) P75 WAN LED issue
On Tue, 10 Feb 1998 21:10:32 -0800
"Kevin A. Smith" <kevin@ascend.com> wrote:
> At 08:09 PM 2/10/98 -0600, Erick M. Bergquist wrote:
> >Hello,
> >
> > I have a Pipeline 75 (older model with power switch) where the WAN LED
> >always stays on yet the unit functions fine. Have upgraded to current
> >version of code and still have problem. The WAN LED stays on even when
> >there are no cables plugged in the ISDN ports. It works fine but is in a
> >end-user environment and they get charged when they are online so with the
> >WAN light always on they don't know if its connected or not unless they
> >telnet in and check the display. Any ideas or this unit bad?
>
> I would suggest RMAing the unit in that case.
>
Yah, I saw the same on a P-25 not so long ago.
--