Real Time Ascend Maling List Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) SNMP Question




Thanks all for the help and suggestions.  
I found the code for disconnecting users using snmpset, it is 
# snmpset max1 Read/WriteComm_Password .1.3.6.1.4.1.529.12.3.1.3.294202029 i 1
and yes 294202029 is the session ID.  Now I will finish writing the perl script
for disconnecting users with double logins and for monitoring total logins so 
I know when it is time to add more equipment.
Thanks again 

  Sonny 

At Tue, 20 Jul 1999 08:36:28 -0500
jcoy@anc.net wrote:
> That only works on a per-chassis basis on a Max4000/6000.
> If a customer dials into multiple chassis with the same
> username, shared profiles = no won't help.
> 
> Ascend/Lucent should consider putting a feature in the code
> that allows chassis to communicate with one another to
> determine multiple logins.
> 
> John
> 

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>