RE: (ASCEND) Any problems with Max 4004 w/72 ports?
Hello,
> -----Original Message-----
> From: root [mailto:root]On Behalf Of andrew
> Sent: Donnerstag, 10. Juni 1999 01:06
> To: ascend-users@max.bungi.com
> Subject: (ASCEND) Any problems with Max 4004 w/72 ports?
>
>
> We are thinking of getting a MAX 4004 with 72 ports, found one at a good
> price. However, I have heard that the 4000 series don't have quite enough
> processing power for the 72 lines. What I am wondering is if anyone out
> there is running these and whether you are having any problems with them.
> Andrew Fresh
>
we have several MAX4000 Systems running. If you have more than two E1 ports
running (analog vs. ISDN is 50:50) you will run into problems. The MAX4000
has
not enough power (even with an additional HDLC card).
We had running a M4K with 2 E1 Ports and one E1 leased line to our backbone,
resulting in many complaints from our users. So we switched the backbone
link to a cisco.
The maximum amount of ISDN channels is 96, even if you have 4 E1 Ports. The
97th caller gets a busy signal.