Real Time Ascend Maling List Archive
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: (ASCEND) Problems around 64 users with 6000 & 7.2.3



We had almost the same problem with 4 PRI lines, and it turn out to be the one of the PRIs had a bad wire (from smart jack to telco block) and replacing fixed the problem (after rebooting the unit!).

I hope it helps.

Gent



At 03:47 PM 1/11/00 -0500, Bob Applegate wrote:
>We've got a very weird problem that we haven't been able to get
>a good handle on.  We have three sites; two have MAX 4048s and
>one has a 6000.  The 6000 has three PRI lines, five 16 port V.90
>cards, and runs TAOS 7.2.3.
>
>Every afternoon when the 6000 gets around 64 users, users who call
>in get connected, then dropped immediately.  It looks like the modems
>negotiate, but the MAX dumps the calls right after that.
>
>I have the Ascend Radius daemon running, and are logging everything.
>We're getting lots of entries like these...
>
>Jan 11 15:42:53 allowaymax Backoff Q full, discarding user
>madhorse[316121249]
>Jan 11 15:43:17 allowaymax ASCEND: call 79 CL 0K  u=qiserv c=185 p=60
>s=64000 r=64000  h=X.X.X.X
>Jan 11 15:43:17 allowaymax ASCEND: slot 9 port 1, line 1, channel 15, Call
>Disconnected [MBID 179; 8562231491->4313]
>Jan 11 15:43:17 allowaymax Backoff Q full, discarding user
>cmcnamee[316121239]
>
>Is this all normal?
>
>Does anyone have any suggestions where to start?  The other MAXes
>work so well that we've never had to debug anything with them, and
>we're a bit overwhelmed by the odd problems we're seeing.
>
>Thanks,
>
>Bob
>
>
>++ Ascend Users Mailing List ++
>To unsubscribe: send unsubscribe to ascend-users-request@bungi.com
>To get FAQ'd:   <http://www.nealis.net/ascend/faq>

++ Ascend Users Mailing List ++
To unsubscribe:	send unsubscribe to ascend-users-request@bungi.com
To get FAQ'd:	<http://www.nealis.net/ascend/faq>